Rule ID
SV-285760r1272392_rule
STIG
Rancher Government Solutions (RGS) Harvester Government CTR Security Technical Implementation GuideVersion
V1R1
Terminating an idle session within a short time period reduces the window of opportunity for unauthorized personnel to take control of a management session enabled on the console or console port that has been left unattended. In addition, quickly terminating an idle session will also free up resources committed by the managed network element. Terminating network connections associated with communications sessions includes, for example, de-allocating associated TCP/IP address/port pairs at the operating system level, or de-allocating networking assignments at the application level if multiple application sessions are using a single, operating system level network connection. This does not mean that the application terminates all sessions or network access; it only ends the inactive session and releases the resources associated with that session. Satisfies: SRG-APP-000190-CTR-000500, SRG-APP-000401-CTR-000965, SRG-APP-000880-CTR-000290
Verify time to live (TTL) (in minutes) on a user auth session. 1. Access the Rancher MCM managing Harvester Government. Navigate to the hamburger menu >> Global Settings. 2. Locate the "auth-user-session-ttl-minutes" setting. If "auth-user-session-ttl-minutes" is not configured to "10" (or less) minutes, this is a finding.
Configure the TTL (in minutes) on a user auth session. 1. Access the Rancher MCM managing Harvester Government. Navigate to the hamburger menu >> Global Settings. 2. Locate the "auth-user-session-ttl-minutes" setting. 3. Select the ellipsis (…) to the right of the parameter and select "Edit Config". 4. Edit the setting and configure it for 10 (or less) minutes. 5. Click "Save".